Overview

Product name: EasyStep Human 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
Reactivity: Human
Alternative Names: 25 Hydroxy Vitamin D;
Assay Type: Competitive Inhibition
Sensitivity: 7.7 ng/mL
Standard: 5000 ng/mL
Detection Range: 78.13-5000 ng/mL
Sample type: Serum, plasma
Assay length: 1.5h
Research Area: Reproductive science;Genetic science;Nutrition metabolism;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human 25-OH-D antigen, and the Human 25-OH-D standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human 25-OH-D to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Human 25-OH-D in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
5000.00 0.221 0.000
2500.00 0.411 0.000
1250.00 0.711 0.000
625.00 0.959 0.000
312.50 1.253 0.000
156.25 1.579 0.000
78.13 1.761 0.000
0.00 2.375 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant 25-OH-D and the recovery rates were calculated by comparing the measured value to the expected amount of 25-OH-D in samples.
Matrix Recovery range Average
serum(n=5) 78-93% 85%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 87-95% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 25-OH-D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-104% 82-96% 95-102%
EDTA plasma(n=5) 90-99% 83-97% 81-103% 89-101%
Heparin plasma(n=5) 88-98% 87-103% 89-97% 85-94%