黄色网站看片欧美-成人大片男人的天堂-女人被免费看在线看-在线观看视频一区网-日日摸日日添日日透 情久久国产视频网站上,青青青国产在线视频在线观看,久久99中文字幕久久,亚洲不卡免费视频

產(chǎn)品中心

去氨精氨酸加壓素(DDAVP)酶聯(lián)免疫吸附檢測(cè)試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK7864
規(guī)格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: DDAVP(1-Desamino 8D Arginine Vasopressin) ELISA Kit
Reactivity: General
Alternative Names: d-DAVP; Stimate; Minirin; Desmopressin
Assay Type: Competitive Inhibition
Sensitivity: 38.4 pg/mL
Standard: 10000 pg/mL
Detection Range: 156.25-10000 pg/mL
Sample type: Serum, plasma and other biological fluids.
Assay length: 2h
Research Area: Metabolic pathway;Endocrinology;Cardiovascular biology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with DDAVP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to DDAVP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of DDAVP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
10000.00 0.219
5000.00 0.433
2500.00 0.711
1250.00 0.959
625.00 1.275
312.50 1.565
156.25 1.835
0.00 2.316

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant DDAVP and the recovery rates were calculated by comparing the measured value to the expected amount of DDAVP in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 87-99% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DDAVP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-107% 83-99% 80-95% 87-96%
EDTA plasma(n=5) 85-92% 79-96% 89-100% 85-96%
Heparin plasma(n=5) 91-99% 85-97% 85-94% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉